Allen-Bradley 1756-L55M14: The ControlLogix5555 Processor with 3.5 MB Memory Explained
Description
Allen-Bradley 1756-L55M14: The ControlLogix5555 Processor with 3.5 MB Memory Explained

The Allen-Bradley 1756-L55M14 is a Logix5555 processor module from Rockwell Automation’s classic ControlLogix platform. It pairs the 1756-L55 controller base with a 1756-M14 memory board to deliver 3.5 MB of user memory, making it one of the most widely used CPUs in legacy mid-size automation systems.
What Is the 1756-L55M14?
The 1756-L55M14 is a ControlLogix 5555 processor:
- 1756-L55 = CPU base (Logix5555 architecture)
- M14 = 3.5 MB battery-backed RAM memory board installed on the CPU
- No on-board non-volatile flash by default — program retention relies on the controller battery (1756-BA1 / 1756-BATM)
It mounts in a standard 1756 ControlLogix chassis (A4/A7/A10/A13/A17 racks) and executes logic under RSLogix 5000 (up to roughly v16 firmware; not supported by Studio 5000 v17+).
Key Specifications
|
Parameter
|
1756-L55M14
|
|---|---|
|
Platform
|
ControlLogix (Logix5555)
|
|
User memory
|
3.5 MB (battery-backed RAM)
|
|
I/O memory
|
~208 KB
|
|
Max I/O points
|
128,000 (4,000 AI / 2,000 AO)
|
|
Scan time
|
~0.08 ms typical bit logic
|
|
Comms
|
RS-232 (CH0); Ethernet/ControlNet/DeviceNet via add-on modules
|
|
Backplane current
|
1.23 A @ 5V, 0.014 A @ 24V
|
|
Battery
|
1756-BA1 / 1756-BATM
|
|
Temp range
|
0–60 °C operating
|
|
Status
|
Discontinued by Rockwell
|
Why the 1756-L55M14 Still Matters
Proven Mid-Tier Control Power
For years, the L55M14 was the sweet spot for line control, batch systems, and machine supervision — enough memory for complex routines without jumping to the larger L6x/L7x tiers.
Battery-Backed Program Model
The 3.5 MB RAM is fast and editable, but depends on a healthy lithium battery. With a good battery and clean power, the controller retains the project through shutdowns.
Drop-In to Existing 1756 Racks
It uses the same chassis, backplane, power supply, and I/O modules as other ControlLogix generations — ideal as a like-for-like spare while a plant delays a full migration.
Network Flexibility via Modules
No native Ethernet port, but with 1756-ENBT/EN2T, CNB, or DNB cards it talks EtherNet/IP, ControlNet, and DeviceNet — enough for most legacy integrations.
Typical Application Scenarios
Manufacturing Lines
Packaging, conveying, assembly, and batch sequencing where RSLogix 5000 v13–v16 projects are already validated.
Power & Utility Aux Systems
Switchgear interlocks, motor control centers, turbine aux controls, and substation SCADA front-ends built on ControlLogix 5555.
Oil & Gas and Compressor Stations
Pipeline compressor control, ESD aux logic, and vendor-package controllers that were shipped with L55-class CPUs.
Legacy System Life-Extension
Many 90s/2000s ControlLogix panels are still running. A tested L55M14 keeps the system alive while the migration business case is evaluated.
Migration Path (When You’re Ready)
If you’re outgrowing 3.5 MB or fighting spare availability:
- Short-term: 1756-L62 (4 MB) or 1756-L63 (8 MB) in same chassis (firmware/project update required)
- Modern drop-in: 1756-L71/L73/L74 (Logix5570, built-in Ethernet, larger memory)
- Current gen: 1756-L8x (Logix5580) with Studio 5000, CIP Security, redundant RM2
Note: L55 → L7x/L8x is not a pure download. You’ll need a controlled project migration, tag reconciliation, and firmware alignment.
Conclusion
The Allen-Bradley 1756-L55M14 is a field-proven ControlLogix5555 CPU with 3.5 MB of battery-backed memory. It remains a practical spare for legacy 1756 racks and a low-risk way to keep an aging automation system running — as long as you source tested units and respect its battery/firmware limits.
For plants not ready to migrate, stocking a verified L55M14 is cheaper insurance than an unplanned shutdown.
FAQ
Is the 1756-L55M14 still manufactured?
No. Rockwell discontinued the L55 family. Available units are refurbished, surplus, or repaired stock.
Does it have built-in Ethernet?
No. Use a 1756-ENBT/EN2T module in the chassis for EtherNet/IP.
What software programs it?
RSLogix 5000 up to ~v16. It is not supported on Studio 5000 v17+.
What battery does it use?
1756-BA1 or 1756-BATM lithium battery; replace before it flags LOW BAT.
Can I just swap the M14 board for more memory?
No. Memory tier is tied to the CPU configuration; field-upgrading usually means replacing the whole controller.
Reviews (0)
Be the first to review “Allen-Bradley 1756-L55M14: The ControlLogix5555 Processor with 3.5 MB Memory Explained” Cancel reply
Shipping and Delivery
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
ABB TVOC-2-240 VOC Sensor for Industrial Air Quality Monitoring
ABB TVOC-2-240 ABB VOC Detector Fast Shipping Global Delivery
ABB TVOC-2-240 Industrial VOC Monitoring Module ABB Original In Stock
ABB TVOC-2-240 1SFA664001R1001 VOC Gas Detector Air Quality Sensor
ABB CP800 ABB Control Panel DCS System Compatible
BENTLY 3500-15 114M5335-01 Power supply module
ABB PM864AK01 3BSE01816R1 Controller module.
Wine bottle lantern
NT$399
Rated 4.00 out of 5


Reviews
There are no reviews yet.